25mm, 38mm and 50mm are common depths of moulded GRP grating, but choosing between them is not simply a case of deciding how heavy-duty the application is.
Panel depth affects load performance and deflection, but so do the clear span between supports, the mesh configuration and the way the grating will be loaded.
A deeper panel can generally accommodate different combinations of load and span, but that does not mean 50mm grating is automatically the right choice for every demanding application. The panel needs to be selected against the actual requirements of the project.
What Do 25mm, 38mm and 50mm Refer To?
The measurement refers to the depth of the GRP grating panel.
Our standard 25mm and 38mm moulded grating has a 38 x 38mm mesh with a 32 x 32mm open hole. Our standard 50mm grating has a 50 x 50mm mesh with a 42 x 42mm open hole.
The standard panel weights also differ:
- 25mm GRP grating – 12.1kg/m²
- 38mm GRP grating – 18.2kg/m²
- 50mm GRP grating – 23.5kg/m²
Depth therefore changes more than the physical height of the panel. The different products also have different weights, mesh configurations and published load performance.
How Does Panel Depth Affect Load Performance?
The difference becomes clearer when the three depths are compared at the same clear span and under the same uniformly distributed load.
At a 600mm clear span under a uniformly distributed load of 1,000kg/m² (9.8kN/m²), our published figures show:
| GRP Grating Depth | Clear Span | Uniformly Distributed Load | Deflection |
|---|---|---|---|
| 25mm | 600mm | 1,000kg/m² (9.8kN/m²) | 6.35mm |
| 38mm | 600mm | 1,000kg/m² (9.8kN/m²) | 2.3mm |
| 50mm | 600mm | 1,000kg/m² (9.8kN/m²) | 1.3mm |
The span and applied load are identical in each case, but the resulting deflection is different.
This is one reason panel depth needs to be considered alongside the required support spacing and acceptable deflection rather than simply choosing a thickness from the application description.
When Is 25mm GRP Grating Considered?
25mm GRP grating is the shallowest of the three standard depths compared here.
Its lower panel weight can be useful where the required loading and support spacing fall within its published performance data. At 12.1kg/m², it is considerably lighter than the 38mm and 50mm products.
However, increasing the clear span has a noticeable effect on deflection.
For example, under a uniformly distributed load of 500kg/m² (4.9kN/m²), the published deflection for 25mm grating increases from 1.7mm at a 500mm clear span to 3.05mm at 600mm and 5.59mm at 700mm.
The published table does not recommend that load at spans of 800mm and above.
This does not make 25mm grating unsuitable as a product. It means its use needs to match the available support spacing and required loading.
When Is 38mm GRP Grating Considered?
38mm GRP grating provides different load and deflection performance while retaining the 38 x 38mm mesh used by the standard 25mm product.
Using the same 500kg/m² uniformly distributed load, the published figures for 38mm grating include 2.1mm deflection at a 700mm clear span, 3.4mm at 800mm, 5.2mm at 900mm and 7.8mm at 1,000mm.
This can make 38mm grating suitable where the required combination of span and loading falls outside the published performance of the 25mm panel.
Again, the correct selection depends on the project rather than treating 38mm as a default thickness.
When Is 50mm GRP Grating Considered?
50mm GRP grating is the deepest of the three standard products covered by our load tables and uses a 50 x 50mm mesh.
Its published performance allows different combinations of span and uniformly distributed load to be considered.
At 500kg/m² (4.9kN/m²), for example, the published deflection is 4.4mm at a 1,000mm clear span, 6.4mm at 1,100mm, 9mm at 1,200mm and 11mm at 1,400mm.
That does not mean 50mm should automatically be used whenever a long span or higher load is involved. The required deflection, support layout, mesh and overall application still need to be checked.
Is Thicker GRP Grating Always Better?
No.
Specifying a deeper panel than the application requires does not automatically improve the overall design. It increases the panel depth and weight and may be unnecessary if a shallower grating already meets the required load, span and deflection criteria.
The aim is to select a panel that performs correctly for the installation rather than simply choosing the deepest available option.
Support Spacing Can Change the Choice of Panel
The supporting structure is an important part of the decision.
If support positions are already fixed, the required clear span may determine which grating depths can be considered. Where a new structure is being designed, there may be more scope to alter support spacing to suit the required grating performance.
For example, reducing the distance between supports can reduce panel deflection and may allow a different grating depth to be used.
This is why grating selection and support layout are best considered together on new GRP walkways, platforms and access structures.
Panel Depth Does Not Tell You Everything
Two products with the same nominal depth should not automatically be treated as having identical performance.
Mesh configuration and product construction also matter. Our standard 25mm and 38mm panels use a 38 x 38mm mesh, while the 50mm panel covered by our standard load table uses a 50 x 50mm mesh.
Other products such as mini mesh, solid-top panels and high-load grating have different constructions and should be assessed using the performance information for the specific product.
It is therefore better to specify the actual grating product and its published data than to specify a panel solely as “38mm GRP grating” or “50mm GRP grating”.
What About Concentrated Loads and Forklifts?
The figures discussed above are based on uniformly distributed loads.
If the grating will support equipment feet, wheels, trolleys or another concentrated load, the loading condition needs to be considered separately. A total weight should not simply be converted into kg/m² and compared with a uniformly distributed load table.
Forklift traffic requires particular consideration because wheel loads are concentrated rather than evenly distributed across the grating.
For these applications, see our High Load Capacity GRP Grating.
How Do You Choose Between 25mm, 38mm and 50mm GRP Grating?
Start with the requirements of the installation.
The information needed includes:
- the clear span between supports
- the load the grating needs to accommodate
- how the load will be applied
- the permitted deflection
- the required mesh or opening size
- the existing or proposed support arrangement
- the environment and intended use of the grating
These details can then be checked against the performance of the available panels.
Our GRP Grating Load Tables provide the published load and deflection figures for standard 25mm, 38mm and 50mm moulded grating.
If you are unsure which depth is appropriate, contact GRP Grating Systems with the required dimensions, loading and support details so the application can be reviewed.
25mm, 38mm & 50mm GRP Grating FAQs
Can I replace existing GRP grating with a different depth?
Potentially, but the replacement should not be selected on depth alone. The clear span, loading, support arrangement and required panel dimensions should be checked before changing from one grating depth to another.
Can different depths of GRP grating be used on the same project?
Yes. Different areas of a project can have different spans, loads and support arrangements, so the same grating depth may not be required throughout. Each area should be assessed against its own requirements.
What if the existing support spacing cannot be changed?
If the support positions are fixed, the grating needs to be selected to suit the available clear span and required loading. The published load and deflection data can then be used to compare suitable panel options.
Does changing GRP grating depth affect the finished floor level?
It can. Moving from a 25mm panel to a 38mm or 50mm panel changes the overall depth of the grating. This may need to be considered where the grating meets existing floors, landings, thresholds or other fixed levels.
What information should I provide when choosing between 25mm, 38mm and 50mm grating?
Provide the clear span, expected loading, dimensions of the area and details of the supporting structure. It is also useful to identify any fixed floor levels, cut-outs, equipment or concentrated loads that could affect the panel selection.